Articles · Nov 23, 2026
Grease Traps for Cafes from July 1, 2026: Resolution No. 589 and a 10-Point Checklist
Since July 1, 2026, food businesses can only connect to the city sewer if they have a grease trap, and it must be cleaned at least once a month. Below: a 10-point checklist, a maintenance schedule, a sample log and a cost estimate in UZS.

Under Cabinet of Ministers Resolution No. 589 of 16.09.2025, from July 1, 2026 only food businesses with a grease trap can be connected to the centralized sewer system. The trap must be cleaned at least once a month, and waste fat must be recycled or handed over for disposal. The deadline has already passed, so below you'll find a 10-point checklist, a maintenance schedule, a sample log and a cost estimate in UZS.
What Resolution No. 589 changed, and why the news gives two dates
The key document is Cabinet of Ministers Resolution No. 589 of 16.09.2025, "On measures for the efficient use of food waste generated at catering establishments…". It came into force on 17.09.2025. For kitchens, it sets requirements for grease traps, on-site wastewater treatment, smoke and odor control, and food waste.
What this means for owners:
- A grease trap is now a condition for sewer connection. From July 1, 2026, food businesses are connected to the centralized sewer only if they have a grease trap. According to Spot (26.06.2026), without one you won't be connected to Uzsuvtaminot networks. We found no reports of the deadline being postponed.
- Cleaning at least once a month. Used oils and fats must be recycled (for example, into household soap or animal feed) or disposed of, not poured into the sewer.
- You install the equipment. As buxgalter.uz notes, businesses install the grease trap at their own expense and are responsible for keeping it in working order.
- On-site treatment. If wastewater is more polluted than the norm allows, it must first be treated on site. For a cafe, that's the reason to fit a grease trap on the kitchen outlet.
Why some sources say January 1 and others July 1. Most likely, these are two different clauses. January 1, 2026 was the deadline for adding ventilation and air-cleaning requirements to sanitary rules (SanPiN) and building codes. July 1, 2026 is the deadline for grease traps and sewer connections. Some media linked January 1 to grease traps, which is inaccurate. We reached this conclusion by comparing several summaries, so check the clause numbers against the resolution text on lex.uz.
Do's and don'ts
Do:
- check that a grease trap is installed on the kitchen outlet and keep its technical passport;
- clean it at least once a month and record every cleaning in a log;
- hand over waste fat, with a signed transfer record, to a contractor who recycles or disposes of it;
- ask your water utility for the technical requirements for your address.
Don't:
- pour deep-fryer oil or fat from the kazan down the sink, even if you have a grease trap;
- confuse the grease trap on the drain with the grease filters in the hood. They are two different devices, and one doesn't replace the other;
- pay an on-the-spot "fine" to someone who claims to be an inspector. Check their authority first, as described in our article on fake gas inspections.
10-point checklist for owners
| # | What to check | Evidence |
|---|---|---|
| 1 | A grease trap is installed on the kitchen outlet: under the sinks or on the main outlet | Photos, connection diagram |
| 2 | Capacity and flow rate match your peak discharge | Product passport, supplier's calculation |
| 3 | You have a connection contract or the water utility's technical requirements | Contract, technical requirements |
| 4 | Cleaning at least once a month | Log entries |
| 5 | You have a contractor for pumping out and removing fat | Contract, transfer records |
| 6 | A responsible person is assigned, usually the head chef or sous chef | Internal order or job description |
| 7 | Sinks have strainers, so food scraps don't go down the drain | Inspection |
| 8 | Fryer oil and kazan fat are collected in a separate container | Labeled container, handover record |
| 9 | Hood filters are clean and the extraction works | Log entry |
| 10 | If you cook on gas, charcoal or wood (grill, tandoor), you have a smoke and odor control unit or a plan to install one | Passport, estimate |
Maintenance schedule: daily, weekly, monthly
Resolution No. 589 sets the minimum: cleaning once a month. The European standard EN 1825-2 also treats once a month as the minimum and recommends cleaning every two weeks. In a kitchen that fries and cooks plov every day, every two weeks is a sensible target.
- Daily (cook at closing): empty the sink strainers, pour fryer oil and kazan fat into a separate container, wipe the grease filters in the hood above the fryer.
- Weekly (responsible person): open the grease trap lid, check the layer of fat and sediment, the smell and how fast it drains. Remove and wash the hood filters.
- Every 2–4 weeks (contractor or trained staff member): empty, clean, refill with clean water, record it in the log, get a transfer record for the removed fat.
- Quarterly: inspect the tank, seals and baffles; compare the fat volume in transfer records with oil usage in your inventory.
The last point is easiest to handle through your inventory system. If oil is written off according to the recipe cards for plov and lagman, you can see how much oil was used each month. If usage goes up but the amount you hand over stays about the same, find out where the difference is going.
Grease trap maintenance log: a template
We found no officially approved log form. Below is a version that follows EN 1825 practice and shows that monthly cleaning actually takes place. Keep it on paper or in a shared spreadsheet, and attach a transfer record to each entry.
| Date | Work done | Fat/sediment volume | Done by | Fat handed to, record No. | Signature of responsible person |
|---|---|---|---|---|---|
| __.__.2026 | Emptied, cleaned, refilled with water | … L | Contractor, full name | Company name, record No. … | Head chef |
| __.__.2026 | Inspection, hood filters washed | — | Sous chef | — | Head chef |
The sources we found don't say how long records must be kept. A practical rule: keep the log together with the transfer records long enough to show them during an inspection.
Cost estimate in UZS: a 40-seat cafe
Take a 40-seat cafe in Samarkand: plov, lagman, samsa, a deep fryer, two sinks. The prices below are guide figures from the Prom.uz, Ecobak and Stroyka.uz catalogs. Some listings date from 2022, so request up-to-date quotes before buying.
| Item | Option A: under-sink | Option B: central underground |
|---|---|---|
| Grease trap | 2 × 50 L plastic at 1,700,000 = 3,400,000 UZS | Underground 1 m³, 5.5 m³/h — 14,500,000 UZS |
| Wall-mounted hood 1000×1200×400 (stainless steel) | 4,410,000 UZS | 4,410,000 UZS |
| Total equipment | 7,810,000 UZS | 18,910,000 UZS |
| Per seat | ≈ 195,000 UZS | ≈ 473,000 UZS |
| Installation, pumping, removal | Per contractor's estimate; get several quotes that include the price per visit | |
For reference: under-sink models start at 1,200,000 UZS, AVS AGRO costs 5,200,000 UZS, an automatic grease trap 19,750,400 UZS, and a small 1000×800×400 hood 2,940,000 UZS. Whether Option A is enough depends on the water utility's requirements and your discharge volume, so confirm this before you buy. If utility bills are also part of your budget, see our breakdown of gas and electricity prepayment.
Ventilation and smoke control: what we know so far
According to Gazeta.uz's summary of the Uzbek version of the resolution, a business must install devices that capture pollutants and odors if it cooks on gas, or, where there is no gas, on wood or charcoal. Other media word it more broadly: open fire, gas, charcoal, wood. Whether this covers a standard gas stove needs to be checked in the resolution text. For charcoal and wood cooking, all summaries agree the requirement applies.
The available sources give no specific ventilation parameters (air exchange rate, filter class), and we found no adopted amendments to building codes (ShNK) or SanPiN. So we don't quote any ventilation figures here. For now, keep your extraction system and hood filters in working order and watch for updates on lex.uz.
FAQ
Does the requirement apply to cafes that are already open?
The resolution names the grease trap as a condition for sewer connection. Not pouring fat down the drain and cleaning the trap monthly is a sensible practice for everyone. Check your premises' status with the water utility.
How often should a grease trap be cleaned?
Under Resolution No. 589, at least once a month. With deep frying and daily plov, every two weeks is better, as EN 1825-2 recommends.
What is the fine for not having a grease trap?
We found no separate penalty specifically for not having a grease trap in published materials. One practical risk is being refused a sewer connection.
Are a grease trap and a hood filter the same thing?
No. A grease trap catches fat in wastewater; a hood filter catches fat in the air. The resolution requires a grease trap on the drain.
Is a grease trap mandatory for cafes, and from when?
Yes. Under Resolution No. 589, from July 1, 2026 only food businesses with a grease trap can connect to the centralized sewer. It must be cleaned at least once a month, and used fat must be recycled or disposed of.
Next steps
Start by covering the 10 checklist points and setting up the log. Then look at where your oil goes. If you run inventory and recipe cards in a system, oil usage per dish is visible in your records and can be matched against fat transfer records. Check out AliPos pricing: inventory and recipe cards are included in Standard, from $39 per month. Or leave a request, and we'll show you how it works with your menu.